products
HomeProductsTerminal electricalSurge protectorsRed Electric Surge 18 width 2P/4P

Red Electric Surge 18 width 2P/4P

Electric Surge protection modules (surge protectors) are mainly suitable for electrical lines with a frequency of 50Hz (or 60Hz) and a surge current capacity not exceeding 200kA. They limit the amplitude of transient overvoltages, absorb, consume, or discharge the energy of surge currents, so that in locations with high overvoltage categories, the protected electrical components can be transitioned from one overvoltage category to a lower one. They are applicable for protecting home and similar venue appliances against induced lightning overvoltages and operational overvoltages in the lines.

Product Core Advantages

Normal Operating Conditions and Installation Conditions
①Ambient Temperature is: -40°C~+80°C.
②Altitude not exceeding 2000m。
③Relative Humidity not exceeding 90%(25°C).
④Installation method is compatible with TH35mm wide rail.
⑤Suitable Grounding Pump Flow "IT”"TT.TS,TN-N-S"
⑥The tilt angle with the vertical plane does not exceed 50 degrees.
⑦A place without shock vibration or shaking."
⑧In a medium without the risk of candle explosion, and free from gases
and dust that are sufficient to corrode metals and damage insulation.

Product Details

Main Technical Specifications are shown in Table 1 (for example)

Wiring Diagram

Main Structure and Working Principle
In a three-phase four-wire system, three phase lines and one neutral line are all equipped with protectors connected to the ground. Under normal conditions, the protectors are in a high-resistance state. When the power grid experiences surge overvoltages due to lightning strikes or other reasons, the protectors will rapidly conduict within nanoseconds, diverting the surge overvoltage into the earth, thereby protecting the electrical equipment on the grid. Once the surge Voltage passes through the protector and disappears, the protector returns to a high-resistance state, thus not affecting the normal operation of the power grid. The electrical schematic of the surge protector is shown in the figure below.

Installation Methods and Precautions

(1). The connecting wires should be of the same capacity as or greater than the power supply lines, and the total length should be controlled within 0.5 meters, with shorter lengths being preferable.
(2). A corresponding circuit breaker or fuse must be connected in series at the front end of the surge protector.
(3). Power must be disconnected during installation.
(4). Surge Protector Troubleshooting
①The indicator window of the module is green (normal); when the module deteriorates, the indicator window turns red and must be replaced promptly.
②Surge protectors can be equipped with (FS) remote telesignal alarm
systems. The telesignal contact points consist of one normally open and one normally closed contact. If a module or multiple modules of the surge protector fail, the contact points will close, triggering a fault alarm signal, indicating that the module has malfunctioned and needs to be replaced.
③Regularly inspect the circuit breakers or fuses connected in series with the line. 

Outer dimensions (length x width x height)

small size mold: 90x72x65.5
medium size mold: 90x108x65.5
large size mold: 90x144x65.5

Product Information Download

Online Inquiry

Related Products

White Type1 Electric Surge 2P/4P

White Type1 Electric Surge 2P/4P

Electric Surge protection modules (surge protectors) are mainly suitable for electrical lines with a frequency of 50Hz (or 60Hz) and a surge current capacity not exceeding 200kA. They limit the amplitude of transient overvoltages, absorb, consume, or discharge the energy of surge currents, so that in locations with high overvoltage categories, the protected electrical components can be transitioned from one overvoltage category to a lower one. They are applicable for protecting home and similar venue appliances against induced lightning overvoltages and operational overvoltages in the lines.

Red Electric Surge 27 width 2P/4P

Red Electric Surge 27 width 2P/4P

Electric Surge protection modules (surge protectors) are mainly suitable for electrical lines with a frequency of 50Hz (or 60Hz) and a surge current capacity not exceeding 200kA. They limit the amplitude of transient overvoltages, absorb, consume, or discharge the energy of surge currents, so that in locations with high overvoltage categories, the protected electrical components can be transitioned from one overvoltage category to a lower one. They are applicable for protecting home and similar venue appliances against induced lightning overvoltages and operational overvoltages in the lines.

White Electric Surge 18 width 2P/4P

White Electric Surge 18 width 2P/4P

Electric Surge protection modules (surge protectors) are mainly suitable for electrical lines with a frequency of 50Hz (or 60Hz) and a surge current capacity not exceeding 200kA. They limit the amplitude of transient overvoltages, absorb, consume, or discharge the energy of surge currents, so that in locations with high overvoltage categories, the protected electrical components can be transitioned from one overvoltage category to a lower one. They are applicable for protecting home and similar venue appliances against induced lightning overvoltages and operational overvoltages in the lines.

+86 18817789947

18817789947@outlook.com